
Add to Cart
RAL1003 signal yellow Antimicrobial Powder Coating to protect outdoor metal structures
Under certain conditions, microorganisms such as bacteria, fungi or algae can settle and proliferate
on any imaginable surface where they form a thin mucus layer, the biofilm.
This layer also protects the microorganisms. In the biofilm, their immunity against nutrient shortage,
extreme pH and temperature fluctuations, bactericides, but also UV and X-radiation increases. This
counteracts cleaning and preventive measures that rely on heat, cleaning agents or radiation.
Combating microorganisms continuously by means of antimicrobial powder coating is a suitable
supportive precaution.
Bad symtoms | Possible Cause | Solution |
1.With low power, powder coating is not easy to coated;
| 1. High voltage power supply shortage; | 1.Check the circuit |
2.Grouding is bad; | 2.Remove clutter grouding line | |
3.Compressed air volume is too big, the powder to blow fell &blows away; | 3.Spray appropriate isolation, reduct air convection; | |
4.Powder particle size is too thin; | 4.Add new powder coating, reduce the recovery powder consumption. | |
5.The air temperature is too high; | 5.Powder particles with air water branch of low power, control temperature of spray area; | |
2. Charge repulsion powder repboud from the working surface; | 1.The voltage is too high; | 1. Lower voltage and air volume; |
2.Spray gun from the work location is too close; | 2. Extend the spray gun and artifacts; | |
3. Grouding is bad; | 3.Remove clutter grouding line; | |
4.Powder particle size is too thin, not esay to attach to the workpiece surface; | 4.Add new powder coating, reduce the recovery powder consumption; | |
3. Corner not easy spraying penetration is bad; | 1. The powder amount is too small; | 1. Lower voltage and air volume, increasing the amount of powder; |
2. Grouding is bad; | 2. Adjust the spray gun position; | |
3. The voltage is too high; | 3. Choose small backboard, proper nozzle; | |
4. Spray gun position is not good; | 4.If the corner is more and deeper, then consider friction gun equipment; | |
5. Powder spraying range is too wide; | ||
4.Powder spraying uneven | 1. Air pressure is insufficient; | 1. Cleaning pipeline, spray gun and flowmeter; |
2.Line fault block; | 2.Check the air supply, Exclude water vapor in powder agglomeration; | |
3.Block in the spray gun; | 3.If powder agglomeration, to screen or change new powder coating; |